TemPlant: Technical specifications
|
Implant |
|
|
Dimensions |
34 mm x 13 mm diameter |
|
Weight of implant |
10 gram |
|
Encapsulation: |
Polyurethane with silicone coating |
|
Transmission interval |
32 seconds, 64 seconds, 128 seconds, 256 seconds |
|
Transmission frequency |
30,000 – 30,300 MHz |
|
|
|
|
Maximum number of antennas per receiver |
4 antennas |
|
Maximum number of animals per antenna |
Depends on chosen interval time. Maximum of 10 animals per antenna at 64-second interval. |
|
|
|
|
Life expectancy battery (160 mAh) |
|
|
Interval 64 seconds |
4 months |
|
Interval 4 minutes |
5 months |
|
|
|
|
Life expectancy battery (1 Ah) |
Increased size of the implant |
Interval 64 seconds |
3 years |
|
Interval 4 minutes |
4 years |
|
|
|
|
On-off mechanism |
Reed contact |
|
|
|
|
Temperature measurement |
|
|
Accuracy |
0.1 ˚C |
|
Resolution |
0.02 ˚C |
|
Range |
35 to 45 ˚C, other ranges upon request |
|
Operating temperature of receiver and base plate |
+5 °C to + 50 °C, non-condensing |
|
|
|
|
Antenna |
|
|
Type |
Tuned loop antenna combination with circular polarity |
|
Dimension |
Two round loops, perpendicularly oriented, loop diameter 500 mm |
|
Transmission range |
Max 20 meters (depends on situation) |
|
Maximum distance between antenna and receiver |
100 meters |
|
|
|
|
Software |
|
|
TempControl |
Compliant with Windows 2000 or higher |